For sales and support visit:
hubbellpowersystems.com/contact/

Key Symbols to Anderson Electrical Connectors Catalog Numbers

Aluminum Connectors for Cable*
Conductor Range
Catalog Number Code Aluminum Copper AWG-MCM ACSR AWG-MCM Decimal Range Inches
6** #4-1/0 - 250-400 #4-1/0-4/0 .232 - .398
7 350-600 4/0 - 336.4 .368 - .575
9 600-900 336.4 - 477 .563 - .744
11 900-1250 556.5 - 795.5 .681 - .893
13 1250-1600 715.5 - 1113 .870 - 1.108
15 1500-2000 1113 - 1272 1.081 - 1.293
16 2000-2500 1272 - 1590 1.289 - 1.459
18 2500-3000 1.382 - 1.632
21 - *Decimal Range 1.632 - 1.824
22 - 1.824 - 2.000
2.000 - 2.200
**Multi-rancge is accomplished by reversing the clamping cap.
*The decimal range is to be considered the final criteria for application. The ACSR and aluminum cable ranges will not necessarily fall within the decimal range for all standings.


Bronze Connectors for Cable
Vers-A-Groove Cap Number Cable Range Decimal Range Inches
Small Groove Large Groove
Min. Max. Min. Max.
022 #6 #2 #2 2/0 .162 - .419
025 #4 1/0 2/0 250 MCM .204 - .575
050 1/0 Sol. 4/0 Str. 250 500 MCM .325 - .813
080 2/0 Sol. 500 MCM 500 800 MCM .365 - 1.031
100 4/0 Str. 750 MCM 750 1000 MCM .522 - 1.152
150 250 750 MCM 750 1500 MCM .474 - 1.412
200 500 1500 MCM 1500 2000 MCM .811 - 1.632
Grooves

Bronze Reversible Cable Caps

Unless otherwise indicated all bronze cable connectors have cable sections designed to accommodate a range of conductors. Their wide applications flexibility offers the distinct advantages of reducing stock inventory, and possibility or errors of misapplication. There is no sacrifice of either electrical or mechanical efficiency when using reversible cable caps. This design is field proven by years of trouble free service in locations where severe operating conditions exist.

Our four bolt reversible cable cap design is adequate for high current capacity conductors, yet priced in line with standard duty connectors.

Copper or Aluminum Flat Bar
Code No. Width In Inches*
10 1
14 1 1/2
20 2
24 2 1/2
30 3
34 3 1/2
40 4
50 5
60 6
80 8
100 10
120 12
*Bar thickness & spacing (if same) are added at end of completed catalog number as "14," "12," etc...







Copper or Aluminum IPS Tubing
Code No. IPS Diameter
02 1/4
03 3/8
04 1/2
06 3/4
10 1
12 1 1/4
14 1 1/2
20 2
24 2 1/2
30 3
34 3 1/2
40 4
44 4 1/2
50 5
60 6


Copper or Aluminum Threaded Studs
Code No. Diameter In Inches*
01 1/8
02 1/4
03 3/8
04 1/2
05 5/8
06 3/4
07 7/8
10 1
11 1 1/8
12 1 1/4
13 1 3/8
14 1 1/2
15 1 5/8
16 1 3/4
17 1 7/8
20 2
21 2 1/8
22 2 1/4
23 2 3/8
24 2 1/2
26 2 3/4
30 3
32 3 1/4
34 3 1/2
36 3 3/4
40 4
50 5
60 6
*Threads per inch are added at the end of completed cataolg number as "12," "16," etc. smooth studs are specified by adding "0."
Hubbell Power Systems All contents Copyright© 2001 - Hubbell Incorporated. All rights reserved. Because Hubbell has a policy of continuous product improvement, we reserve the right to change design specifications without notice.
Terms of Use | Contact Us | Site Map
Connectors