Hardware Features

Ratings and Specifications
Rated Maximum Voltage 27kV
Rated Continuous Current 400A
Fault Make Capacity 8kA
Fault Make Capacity Peak 20.7kA
Fault Break Capacity 8kA
Mechanical Operations 30,000
3 Second Withstand Current 8kA
Transformer Magnetizing Current 14A
Cable Charging Current 25A
Line Charging Current 5A
Lightning Impulse Withstand 125kV
60Hz, 1-Minute Withstand Voltage 60kV
Maximum Terminal Pad Load kg (pounds) 14 (30)
Operating Temperature -40°C to 60°C
Weight kg (pounds) 25 (55)

Programming recloser with serial port connections

Automatic operation

In the closed position, the Versa-Tech® Recloser, operates automatically per the user-programmed settings.

Manual operating Handle

The Manual Operating Handle allows manual operation of the recloser with a hotstick.

Non-reclosing lever

The Non-Reclosing Lever is shown above in its normal (or up) position. When this handle is rotated to the down position, the recloser will trip using TCC1 and lockout on any current above the minimum trip. The Non-Reclosing lever does not interfere with the Manual Operating Handle.

Lockout beacon

The Lockout Beacon is a unique feature to aid the utility lineman in identifying a locked out recloser. This highbrightness, sunlight-visible amber LED will flash once every 3 seconds when the recloser has sequenced to lockout. The beacon will continue to flash every 3 seconds until the lineman closes the recloser or 4 hours have passed. After 4 hours, the flashing beacon will automatically shut off. Powered by the recloser's lithium batteries, the beacon's duty cycle was set to have a negligible effect on battery life.

Operations counter

The Operations Counter is an electromechanical counter which records the number of open operations, both manual and automatic, initiated by the control.

Zero service requirements

The Versa-Tech® Recloser has been designed for a minimum mechanical life of 2500 operations. No routine maintenance is required.

8-Year battery replacement

Battery power is used for these functions only: To close the recloser after installation or lockout, the radio if load current is less than 5 amps, and the flashing lockout beacon. The batteries are made of a very stable lithium chemistry, which is designed with a low self discharge that they can function correctly for up to 10 years. Hubbell Power Systems recommends that users replace the batteries on an 8 year cycle.

The battery bayonet was designed to be replaced using a hot stick while the recloser is in service. The battery bayonet utilizes a twist lock design. It is easily removed by pushing in slightly and turning.

Customer-supplied requirements

  • Personal Computer with Microsoft® Windows® 95 or later operating system, a CD-ROM Drive and a RS-232 serial port. (Computers with only USB ports will need RS-232 to USB adapters.)
  • Straight-through DB9 Male/Female serial cable to interface from the PC to the recloser via the serial port, after removing its cover shown as shown.